UL1000 Fab - Economic Helium Vacuum Leak Testing
ULTRATEST™ sensor technology.
The “Dry” Standard for Vacuum Leak Testing in Industrial Vacuum and Semiconductor Manufacturing
The INFICON UL1000 Fab Helium Leak Detector is the renowned standard when it comes to economic helium vacuum leak testing in industrial or semiconductor environments.
Potential contamination of the tested parts or equipment by carbon-hydrogen compounds or particles is eliminated through the instrument’s dry pump technology. The UL1000 Fab provides the best compromise between high performance, unparalleled robustness, and affordability. It provides state-of-the art detection limits of 10-12 mbar*l/s combined with reasonable short pump down and response time. The compact design provides high maneuverability allowing easy access to maintenance areas with restricted space. The selectable background suppression (iZERO) enables continuous leak testing within at least two decades lower than existing background levels.
All features enable you to shorten the time of your leak testing efforts while assuring that all leaks can be identified at an economic scale.
Advantages
- minimize leak testing efforts through quick pump down and response time
- avoid need for multiple leak tests by using selectable background suppression (iZERO)
- enable easy access to maintenance areas with restricted space through maneuverable design
- low total cost of ownership (TCO) enabled by robust two hot filament ion source (3 years warranty) and counterflow vacuum system
- easy to use with rotatable display, optical and audible leak indication, and optional remote control
- low maintenance via a built-in test leak with auto calibration procedure
Typical Applications
- industrial vacuum equipment manufacturing with high demand for cleanliness
- vacuum components or sub-assemblies before they are installed in existing tools
- maintenance work on vacuum tools, with or without support from their own pump
- inspections and installations of process gas systems
- Semiconductor, flat panel display or solar cell manufacturing
Specifications
Min. detectable leak rate for Helium (Vacuum mode) | mbar•L/s | < 5 • 10-12 |
Min. detectable leak rate for Helium (Sniffer mode) | mbar•L/s | < 5·10-8 |
Max. Inlet pressure GROSS mode | mbar | 15 |
Max. Inlet pressure FINE mode | mbar | 2 |
Max. Inlet pressure ULTRA mode | mbar | 0.4 |
Pumping speed during evacuation | m³/h | 25 at 50 Hz |
Helium pumping speed ULTRA mode | L/s | 2.5 |
Detectable masses | 2,3,4 amu | |
Mass spectrometer Sector field | 180° | |
Filaments ion source Iridium/Yttria coated | 2 | |
Calibrated built-in leak | mbar•L/s | ∼ 10-7 |
Test port | DN 25 KF | 1 |
Adjustable triggers | 2 | |
Interface | RS 232 | |
Chart recorder output | V | 2 x10 |
In/Outputs | PLC compatible | |
Permissable ambient temperature (during operation) | °C | +10 to +40 |
Weight | kg lb | 110 242 |
Dimensions (l x w x h) | mm in. | 1050 x 472 x 987 41 x 19 x 39 |
Supply voltage (EU) | V (ac) | 230 (± 10 %) 50 Hz |
Supply voltage (US) | V (ac) | 100/115 V (± 10 %) 50/60 Hz |
Power consumption (typ.) | VA | 1100 |
Power consumption (max.) | VA | 1100 |
Ordering Information
550-100A | UL1000 Fab, 230 V AC, EU plug |
550-101A | UL1000 Fab, 100/115 V AC, US plug |
14022 | Extension cable for remote control RC1000, 8 m length |
551-000 | Toolbox, detachable,for UL1000 |
551-001 | Helium Bottle Holder for UL1000/5000 |
551-002 | ESD Mat for UL1000/5000 |
551-005 | TC1000Test Chamber,DN25KF,ESD wrist band |
551-010 | Remote Control RC1000C, wired, with 4m coiled cable |
551-015 | Remote Control RC1000WL, wireless, incl. wireless transmitter |
551-020 | Wireless transmitter for RC1000WL |
RC1000 Remote Control | RC1000 Remote Control |
TC1000 Test Chamber | TC1000 Test Chamber |
Downloads
Contact us today to discuss the requirements for your custom automation solutions.